PT500-501
Main features:
Adopt imported voltage sensing chip, select the chip technology, with zero, full range compensation, temperature compensation;
High precision stable amplifier IC;
Industrial standard analog quantity 4-20mA or 0-5V / 10V output;
Compact structure, full seal welding structure, impact resistance, fatigue resistance, high reliability;
Common keywords:
Oil pressure sensor
Water pressure transmitter air pressure transmitter
Wind pressure sensor
Matching pressure sensor of air compressor
Product description of strain type pressure transmitter:

Chip:


Imported brand pressure sensitive chip wafer;

Selected chip technology and fully sealed package;

Core:

Diffused silicon core, high sensitivity, large output, zero point, full range compensation, temperature compensation, suitable for small range pressure transmitter;

Strain gauge core, high-strength elastic deformation pressure sensing material, equipped with temperature compensation, has the advantages of impact resistance and fatigue resistance, suitable for general range pressure transmitter;

Ceramic core, outstanding anti-corrosion performance, with zero point, full range compensation, temperature compensation; suitable for measuring medium with strong corrosive working conditions, range less than 5MPa;

Structure:

Small overall structure, diversified process connection modes (thread M20, M16, M12, G1 / 4, G1 / 2, 1 / 2NPT, 1 / 4NPT, flange connection, quick joint, welding, etc.)

The electrical connection is tight nut, direct outgoing line, full welding without movable connection part, and the connection strength between cable sensors is strengthened;

Process connection material: 304 or 316;

Shell material: 304 or 316;

Supporting standard four core shielded cable;

Signal processing:

24 bit ADC sampling processing chip;

DSP digital signal conditioning algorithm;

Multipoint line temperature calibration;

Voltage and current overload protection;

Standard industrial signal output: 4-20mA (two-wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);
Application fields:
  • Air supply system

  • Air compressor unit

  • Gas supply system

  • Constant pressure water supply

Specification parameter
Measurement medium: liquid and gas (compatible with product process connection materials)

Pressure form gauge pressure, absolute pressure

Range: 0-0.6-60mpa

-0.1~0~0.6~5MPa

-100KPa~10KPa~40MPa

±10KPa~±100KPa

Comprehensive accuracy ± 0.25% FS; ± 0.% FS; ± 1% FS

Nonlinear ≤ 0.25% FS

Repeatability ≤ 0.1% FS

Output signal: 4-20mA (two-wire system); 0-20mA (three wire system)

0-5vdc; 0-10vdc (three wire system)

0.5-4.5vdc (three wire system) / 5VDC power supply available

The power supply voltage is 24VDC (9-30vdc) / 5VDC can be used when the output is 0.5-4.5vdc

Insulation impedance ≥ 1000m Ω / 100VDC

Load impedance current output: ≤ 800 Ω; voltage output: ≥ 50K Ω

Medium temperature - 20-80 ℃

Ambient temperature - 20 ~ 70 ℃

Compensation temperature 0-70 ℃

Response time ≤ 5ms

Overload pressure 150% FS

5 times of range (range less than 5MPa); 3 times of range (range greater than 5MPa)

Electrical connection: direct outgoing line of tightening nut

IP 65

Connecting cable: four core shielded cable, standard length: 3M

Connection material 304 / 316L

Process connection m20x1.5, G1 / 2, G1 / 4, ZG1 / 4, 1 / 4NPT


Ordering considerations
1. Product range selection:

In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula:

Range = x (1.2-1.5) times of the maximum system pressure;

The actual measuring pressure range of the product should be 15% - 80% of the range;

2. Signal output mode of the product:

The signal output specification depends on the requirements of the back-end acquisition equipment;

Common are: control and display instrument, PLC acquisition and input module, MCU acquisition card, PC serial port, etc

If the back-end acquisition equipment is determined according to the output specification of the product, it is recommended to use the general two-wire system 4-20mA;

3. The user should understand the measurement medium characteristics of the product:

Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);

4. Users should understand the installation environment and installation method of the product:

Indoor or outdoor installation;

Ambient temperature;

Required sealing level;

Vibration range of equipment;

Installation method: thread, flange, special structure;

Whether the installation space meets the overall dimension of the product;

Whether the installation sequence is: first install the sensor, then cable;
Precautions for use
Product power supply 24VDC (range: 9-30vdc);

It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure core body under pressure measurement output;

The power and signal wires shall be correctly wired according to the specifications of the ordered products;

During product installation, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon;

It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter;

Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead;

The pressure transmitter is a precision measuring instrument, do not impose impact or smash to avoid damaging the core;

The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight;
Common problem
Question 1: no output from pressure transmitter?

Reason/processing method

The power line is connected reversely according to the operation manual / product certificate / product label

Poor wiring of electrical connector: disassemble the electrical connector and check whether the wiring of each terminal pin is firm

Cable open replace cable

Transmitter amplifier board burned out, repaired or replaced


Question 2: is the output of pressure transmitter less than 3.92mA or less than 0VDC?

Reason/processing method

The power supply voltage is less than the required value. The normal minimum power supply voltage is 9VDC. Check the voltage value

The power of power supply is not enough. Does the power of power supply meet the requirements of rated load

Excessive load of acquisition circuit check circuit load

If the pressure value exceeds the minimum range value, is negative pressure formed at the pressure tap of the transmitter

Repair or replace the pressure transmitter amplifier board after burning out

Impact or overpressure core damage repair or replacement


Question 3: pressure transmitter output ≥ 22mA or 5.5VDC/10.5VDC?

Reason/processing method

The power supply voltage is less than the required value. The normal minimum power supply voltage is 9VDC. Check the voltage value

The power of power supply is not enough. Does the power of power supply meet the requirements of rated load

The pressure value exceeds the maximum range value. Check the loading pressure of the pressure transmitter

Repair or replace the pressure transmitter amplifier board after burning out

Impact or overpressure core damage repair or replacement


Question 4: unstable pressure transmitter output?

Reason/processing method

Unstable pressure source check whether the pressure of the pressurization system is stable

There is no grounding wire. The pressure transmitter and equipment are grounded

The installation position of the transmitter has a large magnetic field. Install a shield or replace the installation position

The cable is too long and passes through the magnetic field to replace the cable routing position

Transmitter water inlet or steam transmitter is not powered down into the temperature box, heating 65 degrees for drying

Cleaning of stone sand or sundries in pressurized pipeline

If the pressure medium temperature is too high, check whether the medium temperature is within the allowable range of the transmitter


Question 5: how to install and replace the pressure transmitter?

Reason/processing method

Install (because the cable is not detachable) 1. Install the pressure transmitter first

2. Test whether the process connection of pressure transmitter is sealed

3. Arrange pressure transmitter cable routing

4. Connect the power on test output of acquisition instrument or equipment

5. Normal operation  Disassembly or replacement is reversed from the above installation steps
Proposal
Name
Tel
QQ
WeChat
Mailbox
Address
Content
Foshan puliang Electronic Co., Ltd

Tel:0757-26619568 Fax: 0757-26619508

24-hour online technical support:13790092618

Cloud platform:www.puliangiot.com

Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

Copyright©Foshan puliang Electronic Co., Ltd