Welcome to the website of Foshan puliang Electronic Co., Ltd Mobile           中文   EN
Hot Keywords:Pressuresensor Pressure transmitter level sensor Temperature sensor
PID intelligent pressure control meter PY9000
It integrates a number of international advanced electronic technology, single chip computer technology, electric erasure technology and anti-interference technology;
It has the advantages of high measurement and control precision and strong anti-interference performance;
Precise and stable PID negative feedback control output 4-20mA / 0-10vdc
Double four high brightness green and red LED, display resolution: 0001;
Instrument accuracy: 0.2% FS ± 1 bit;
Sampling speed: 50 times/S;

Common keywords:
PID intelligent pressure control gauge PID negative feedback pressure gauge
Negative feedback pressure controller of PID digital pressure instrument
<
>
  • Product parameters
  • Specification parameter
  • Ordering considerations
  • Precautions for use
  • Common problem
  • Proposal

Model: PY9000 PID negative feedback intelligent pressure control instrument

Display: double layer four digit high brightness green and red LED

Display resolution: 0001
Display range: - 999-9999 MPa (variable decimal point)
Instrument accuracy: 0.2% FS ± 1 bit
Indicator display: accuracy indicator, out output indicator, al1, al2 alarm indicator

Input signal:
1 ~ 4MV / V four wire bridge
4 ~ 20mA two wire system current
Voltage type: 0 ~ 5VDC, 0 ~ 10VDC three wire system
Rs485-rtu digital communication

Supply voltage:
220 VAC (85 ~ 265 VAC) / 50 Hz ~ 60 Hz
24 VDC ± 5% (DC)

Sampling speed: 50 times / S

PID output type:
4-20mA
0-10VDC
0-5VDC

Main alarm output: upper limit alarm has relay output (220V 1a), upper limit alarm indicator (out) is on, and can be equipped with peak value reservation (indicated 

when ordering)
Auxiliary output: the auxiliary output can meet different output requirements through different function modules and instrument settings. See (V) module function 

description section for details. Optional auxiliary output (when ordering)
Alarm range: - 999 ~ 9999 MPa (variable decimal point)
Efficiency indication
(equipped with melt sensor): display 80% of the full scale value of the sensor (the sensor should be unloaded), and the CAE is on
Operating temperature and humidity: 0~55 ℃, ≤80% RH
Dimensions: 96×96×100mm
Opening size: 92×92mm
Self weight: 400g
Application fields:
  • Steam supply system

  • Oil pressure system

  • Air supply system

  • petrochemical industry

  • Casting equipment

  • Extruder equipment

PY900


Display: double layer four digit high brightness green and red LED

Display resolution: 0001
Display range: - 999-9999 MPa (variable decimal point)
Instrument accuracy: 0.2% FS ± 1 bit
Indicator display: accuracy indicator, out output indicator, al1, al2 alarm indicator

Input signal:
1 ~ 4MV / V four wire bridge
4 ~ 20mA two wire system current
Voltage type: 0 ~ 5VDC, 0 ~ 10VDC three wire system
Rs485-rtu digital communication

Supply voltage:
220 VAC (85 ~ 265 VAC) / 50 Hz ~ 60 Hz
24 VDC ± 5% (DC)

Sampling speed: 50 times / S

PID output type:
4-20mA
0-10VDC
0-5VDC

Main alarm output: upper limit alarm has relay output (220V 1a), upper limit alarm indicator (out) is on, and can be equipped with peak value reservation (indicated 

when ordering)
Auxiliary output: the auxiliary output can meet different output requirements through different function modules and instrument settings. See (V) module function 

description section for details. Optional auxiliary output (when ordering)
Alarm range: - 999 ~ 9999 MPa (variable decimal point)
Efficiency indication
(equipped with melt sensor): display 80% of the full scale value of the sensor (the sensor should be unloaded), and the CAE is on
Operating temperature and humidity: 0~55 ℃, ≤80% RH
Dimensions: 96×96×100mm
Opening size: 92×92mm

Self weight: 400g



Precautions for PY9000 product ordering

1. Instrument power supply voltage selection:
220 VAC AC voltage
24 VDC DC voltage

2. Type of instrument input signal (matching with user transmitter / sensor output)
Type of 4-20mA two-wire pressure / liquid level / temperature transmitter
0-5vdc three wire pressure / liquid level / temperature transmitter
0-10vdc three wire pressure / liquid level / temperature transmitter
2.0 / 3.3mV pressure sensor / load cell
Rs485-rtu digital communication signal transmitter

3. Instrument output type (matching with user acquisition and control system)
Two way relay output + PID 4-20mA feedback
Two relay outputs + one relay output
Two way relay output + PID 0-10vdc feedback
Two way relay output + PID 0-5vdc feedback
Two relay outputs + one digital RS485 output

4. Users should understand the installation environment and installation mode of the product
Indoor or outdoor installation (power box protection required);
Ambient temperature;
Vibration range of equipment;
Whether the installation space meets the product dimensions;


The type and scope of instrument power supply shall be provided according to the requirements of instrument;
Instrument 16 foot grounding;
Power supply and signal wire shall be correctly wired according to the requirements of product specification ordered;
The output power of the relay at the output end of the instrument shall not exceed 220v/1a or 24v/1a;
Pay attention to the protection instrument access and outgoing cable. When the span of field use is too large, it is recommended to use metal pipe to protect or overhead;
The product is installed in a ventilated, dry and non corrosive environment. Protective devices are installed in the open air to avoid direct sunlight;
Avoid direct access to user devices or appliances causing interference as far as possible;

Name
Tel
QQ
WeChat
Mailbox
Address
Content